The GM40AV Time Switch is a universal, electromechanical time switch designed for general purpose residential and commercial applications. The robust 40 A time switch automatically detects the input voltage without the use of a DIP switch or selector pins. The time switch automatically selects any voltage between 120-277 VAC. The mechanism is mounted in a compact UL Type 3R outdoor enclosure and can also be easily retrofitted into other Intermatic enclosure types. The time switch features a DPDT switching configuration standard (i.e. two normally open and two normally closed contacts).
- Autovoltage selection 120 VAC-277 VAC
- Captive trippers - trippers cannot be lost
- 40 A rating
- Self-recharging battery backup, "Q" models feature 72-hour carry-over
- Power and status LED indicators
- 24-Hour or 7-day models available
- Up to 48 ON/OFF operations per 24-hour period or 42 ON/OFF operations per week on "W" models
- DPDT switching configuration standard (2 NO and 2 NC Contacts)
- Manual three-way ON/OFF/AUTO override switch
- Easy-to-read clock face
Input Voltage Range(s) | Auto Voltage 120-277 VAC, 60 Hz | Operation Mode | 24 hour |
Mechanism Type | Electromechanical | Wiring Option | Screw box lug |
CA Prop 65 Message | This product is in compliance with Prop65 | California Proposition 65 | None |
Color | Gray | Country of Origin (Intermatic) | MEXICO |
Electrical Life | 50,000 operations at full load | Enclosure Type | Indoor/outdoor type 3R plastic |
Has Captive Trippers | Yes | Has Override Switch | Yes |
Has Real-time Clock Face | Yes | Magnetic Ballast (NC) Range(s) | 10 A, 277 VAC |
Magnetic Ballast (NO) Range(s) | 30 A, 120 VAC; 20 A, 277 VAC | Maximum ON/OFF Operations | 48 |
Minimum ON/OFF Times | 15 min | Motor Load Ratings NC Ranges | 1 HP, 12 FLA, 30 LRA @ 120 VAC; 2 HP, 10 FLA, 30 LRA @ 240 VAC |
Motor Load Ratings NO Ranges | 1 HP, 16 FLA, 90 LRA @120 VAC; 2 HP, 12 FLA, 52 LRA @ 208-277 VAC | Number of Trippers Included | 96 |
Operating Humidity | 0-95% RH, Non-condensing | Other Certifications and Compatibilities | cRUus, Green Energy |
Pilot Duty (NO) | 300 VA, 120 VAC, 300 VA, 208 VAC, 300 VA, 240 VAC | Pilot Duty (NO) Range(s) | 300 VA, 120-240 VAC |
Pilot Duty Load Ratings Ranges | 300 VA, 120-240 VAC | Resistive (NC) Range(s) | 30 A, 120-277 VAC |
Resistive (NO) Range(s) | 40 A, 120-277 VAC | RoHS Certification | Y |
Switch Type | DPDT | Tungsten (NC) Load Ratings | 2 A, 120 VAC |
Tungsten (NO) Load Ratings | 15 A, 120 VAC | UL Certification | cULus |
Voltage Selection Type | Auto Voltage | Warranty Period | 1-Year limited |
Wire Size Max | #8 AWG | Operating Temperature Max (°C) | 55 |
Operating Temperature Max (°F) | 131 | Operating Temperature Min (°C) | -40 |
Operating Temperature Min (°F) | -40 | Product Depth (in) | 3 |
Product Depth (mm) | 7.62 | Product Height (in) | 8.875 |
Product Height (mm) | 225.425 | Product Width (in) | 6.609 |
Product Width (mm) | 16.79 | Unit Carton Height (in) | 9.125 |
Unit Carton Length (in) | 6.75 | Unit Carton Weight (lb) | 1.83 |
Unit Carton Width (in) | 3 | Units Per Pallet | 348 |